{rfName}
Da

Indexed in

License and use

Icono OpenAccess

Altmetrics

Analysis of institutional authors

Estévez, AsAuthorHerrero Bosch VAuthorToledo Alarcón JfAuthor

Share

Publications
>
Article

Data Compression in the NEXT-100 Data Acquisition System

Publicated to:Sensors. 22 (14): 5197- - 2022-07-01 22(14), DOI: 10.3390/s22145197

Authors: Esteve Bosch, Raul; Rodriguez Ponce, Jorge; Simon Estevez, Ander; Benlloch Rodriguez, Jose Maria; Herrero Bosch, Vicente; Toledo Alarcon, Jose Francisco

Affiliations

Abstract

NEXT collaboration detectors are based on energy measured by an array of photomultipliers (PMT) and topological event filtering based on an array of silicon photomultipliers (SiPMs). The readout of the PMT sensors for low-frequency noise effects and detector safety issues requires a grounded cathode connection that makes the readout AC-couple with variations in the signal baseline. Strict detector requirements of energy resolution better than 1% FWHM require a precise baseline reconstruction that is performed offline for data analysis and detector performance characterization. Baseline variations make it inefficient to apply traditional lossy data compression techniques, such as zero-suppression, that help to minimize data throughput and, therefore, the dead time of the system. However, for the readout of the SiPM sensors with less demanding requirements in terms of accuracy, a traditional zero-suppression is currently applied with a configuration that allows for a compression ratio of around 71%. The third stage in the NEXT detectors program, the NEXT-100 detector, is a 100 kg detector that instruments approximately five times more PMT sensors and twice the number of SiPM sensors than its predecessor, the NEXT-White detector, putting more pressure in the DAQ throughput, expected to be over 900 MB/s with the current configuration, which will worsen the dead time of the acquisition data system. This paper describes the data compression techniques applied to the sensor data in the NEXT-100 detector, which reduces data throughput and minimizes dead time while maintaining the event rate to the level of its predecessor, around 50 Hz.

Keywords

Data acquisitionData acquisition circuitData acquisition circuitsData acquisition systemData compressionData compression techniquesData throughputDead timeEnergyEvent filteringField programmable gate arrays (fpga)FpgaPhotomultipliersSiliconSilicon photo multipliers (sipm)Timing circuitsXenonXenon tpcZero suppression

Quality index

Bibliometric impact. Analysis of the contribution and dissemination channel

The work has been published in the journal Sensors due to its progression and the good impact it has achieved in recent years, according to the agency Scopus (SJR), it has become a reference in its field. In the year of publication of the work, 2022, it was in position , thus managing to position itself as a Q1 (Primer Cuartil), in the category Analytical Chemistry.

Independientemente del impacto esperado determinado por el canal de difusión, es importante destacar el impacto real observado de la propia aportación.

Según las diferentes agencias de indexación, el número de citas acumuladas por esta publicación hasta la fecha 2025-05-29:

  • WoS: 1
  • Scopus: 1
  • Europe PMC: 1
  • OpenCitations: 1

Impact and social visibility

From the perspective of influence or social adoption, and based on metrics associated with mentions and interactions provided by agencies specializing in calculating the so-called "Alternative or Social Metrics," we can highlight as of 2025-05-29:

  • The use, from an academic perspective evidenced by the Altmetric agency indicator referring to aggregations made by the personal bibliographic manager Mendeley, gives us a total of: 2.
  • The use of this contribution in bookmarks, code forks, additions to favorite lists for recurrent reading, as well as general views, indicates that someone is using the publication as a basis for their current work. This may be a notable indicator of future more formal and academic citations. This claim is supported by the result of the "Capture" indicator, which yields a total of: 2 (PlumX).

With a more dissemination-oriented intent and targeting more general audiences, we can observe other more global scores such as:

  • The Total Score from Altmetric: 0.5.
  • The number of mentions on the social network X (formerly Twitter): 1 (Altmetric).

It is essential to present evidence supporting full alignment with institutional principles and guidelines on Open Science and the Conservation and Dissemination of Intellectual Heritage. A clear example of this is:

  • The work has been submitted to a journal whose editorial policy allows open Open Access publication.

Leadership analysis of institutional authors

This work has been carried out with international collaboration, specifically with researchers from: Israel; United States of America.

There is a significant leadership presence as some of the institution’s authors appear as the first or last signer, detailed as follows: First Author (Bosch, RE) and Last Author (Alarcon, JFT).

the author responsible for correspondence tasks has been Bosch, RE.