Article
Green

ALBIRA: A small animal PET/SPECT/CT imaging system

Publicat a:Medical Physics. 40 (5): 51906- - 2013-05-01 40(5), DOI: 10.1118/1.4800798

Autors: Sanchez, F; Orero, A; Soriano, A; Correcher, C; Conde, P; Gonzalez, A; Hernandez, L; Moliner, L; Rodriguez-Alvarez, M J; Vidal, L F; Benlloch, J M; Chapman, S E; Leevy, W M

Afiliacions

Ctr Invest Principe Felipe, ONCOVISION - Autor o coautor
Notre Dame Integrated Imaging Facil - Autor o coautor
Univ Politecn Valencia, CIEMAT, Ctr Mixto CSIC, Inst Instrumentac Imagen Mol I3M - Autor o coautor

Resum

Purpose: The authors have developed a trimodal PET/SPECT/CT scanner for small animal imaging. The gamma ray subsystems are based on monolithic crystals coupled to multianode photomultiplier tubes (MA-PMTs), while computed tomography (CT) comprises a commercially available microfocus x-ray tube and a CsI scintillator 2D pixelated flat panel x-ray detector. In this study the authors will report on the design and performance evaluation of the multimodal system. Methods: X-ray transmission measurements are performed based on cone-beam geometry. Individual projections were acquired by rotating the x-ray tube and the 2D flat panel detector, thus making possible a transaxial field of view (FOV) of roughly 80 mm in diameter and an axial FOV of 65 mm for the CT system. The single photon emission computed tomography (SPECT) component has a dual head detector geometry mounted on a rotating gantry. The distance between the SPECT module detectors can be varied in order to optimize specific user requirements, including variable FOV. The positron emission tomography (PET) system is made up of eight compact modules forming an octagon with an axial FOV of 40 mm and a transaxial FOV of 80 mm in diameter. The main CT image quality parameters (spatial resolution and uniformity) have been determined. In the case of the SPECT, the tomographic spatial resolution and system sensitivity have been evaluated with a Tc-99m solution using single-pinhole and multi-pinhole collimators. PET and SPECT images were reconstructed using three-dimensional (3D) maximum likelihood and ordered subset expectation maximization (MLEM and OSEM) algorithms developed by the authors, whereas the CT images were obtained using a 3D based FBP algorithm. Results: CT spatial resolution was 85 mu m while a uniformity of 2.7% was obtained for a water filled phantom at 45 kV. The SPECT spatial resolution was better than 0.8 mm measured with a Derenzo-like phantom for a FOV of 20 mm using a 1-mm pinhole aperture collimator. The full width at half-maximum PET radial spatial resolution at the center of the field of view was 1.55 mm. The SPECT system sensitivity for a FOV of 20 mm and 15% energy window was 700 cps/MBq (7.8 x 10(-2)%) using a multi-pinhole equipped with five apertures 1 mm in diameter, whereas the PET absolute sensitivity was 2% for a 350-650 keV energy window and a 5 ns timing window. Several animal images are also presented. Conclusions: The new small animal PET/SPECT/CT proposed here exhibits high performance, producing high-quality images suitable for studies with small animals. Monolithic design for PET and SPECT scintillator crystals reduces cost and complexity without significant performance degradation. (c) 2013 American Association of Physicists in Medicine.

Paraules clau

AlgorithmAnimalAnimal experimentAnimalsArticleCalibrationCesium iodideComputed tomography scannerComputer assisted tomographyCrystalsCtDevicesEquipmentEquipment designFiltrationFlat-panel x-ray detectorGamma radiationGamma raysImage processingImage processing, computer-assistedImage qualityImage reconstructionImage resolutionInformation processingIntegrated pet/spect/ct scannerIntegrated petspectct scannerMaximum likelihoodMaximum principleMiceModulation transfer functionMouseMulti-anode photomultiplier tubesMulti-pinhole collimatorsMultimodal imagingNonhumanNuclear medicineOptimizationOrdered subset expectation maximizationsParticle beamsPerformance evaluationPet scannerPhantomsPhotomultipliersPinhole spectPositron emission tomographyPositron emission tomography (pet)Positron-emission tomographyPriority journalRadionuclide imagingRatRatsScanningScintillationScintillation countersSensitivity and specificitySensorSingle photon emission computed tomographySingle photon emission computer tomographySmall animal imagingSpect scannerTomography, emission-computed, single-photonTomography, x-ray computedX ray detectorsX ray tubeX ray tubesX rays

Indicis de qualitat

Impacte bibliomètric. Anàlisi de la contribució i canal de difusió

El treball ha estat publicat a la revista Medical Physics a causa de la seva progressió i el bon impacte que ha aconseguit en els últims anys, segons l'agència WoS (JCR), s'ha convertit en una referència en el seu camp. A l'any de publicació del treball, 2013, es trobava a la posició 25/122, aconseguint així situar-se com a revista Q1 (Primer Cuartil), en la categoria Radiology, Nuclear Medicine & Medical Imaging.

Des d'una perspectiva relativa, i tenint en compte l'indicador de impacte normalitzat calculat a partir de les Citacions Mundials proporcionades per WoS (ESI, Clarivate), proporciona un valor per a la normalització de citacions relatives a la taxa de citació esperada de: 2.58. Això indica que, comparat amb treballs en la mateixa disciplina i en el mateix any de publicació, el situa com un treball citat per sobre de la mitjana. (font consultada: ESI 14 Nov 2024)

Aquesta informació es reforça amb altres indicadors del mateix tipus, que encara que dinàmics en el temps i dependents del conjunt de citacions mitjanes mundials en el moment del seu càlcul, coincideixen a posicionar en algun moment el treball, entre el 50% més citats dins de la seva temàtica:

  • Mitjana Ponderada de l'Impacte Normalitzat de l'agència Scopus: 2.49 (font consultada: FECYT Febr 2024)
  • Field Citation Ratio (FCR) de la font Dimensions: 45.5 (font consultada: Dimensions Jul 2025)

Concretament, i atenent a les diferents agències d'indexació, aquest treball ha acumulat, fins a la data 2025-07-04, el següent nombre de cites:

  • WoS: 77
  • Scopus: 88
  • Europe PMC: 30

Impacte i visibilitat social

Des de la dimensió d'influència o adopció social, i prenent com a base les mètriques associades a les mencions i interaccions proporcionades per agències especialitzades en el càlcul de les denominades "Mètriques Alternatives o Socials", podem destacar a data 2025-07-04:

  • L'ús d'aquesta aportació en marcadors, bifurcacions de codi, afegits a llistes de favorits per a una lectura recurrent, així com visualitzacions generals, indica que algú està fent servir la publicació com a base del seu treball actual. Això pot ser un indicador destacat de futures cites més formals i acadèmiques. Aquesta afirmació està avalada pel resultat de l'indicador "Capture", que aporta un total de: 84 (PlumX).

És fonamental presentar evidències que recolzin l'alineació plena amb els principis i directrius institucionals sobre Ciència Oberta i la Conservació i Difusió del Patrimoni Intel·lectual. Un clar exemple d'això és:

  • El treball s'ha enviat a una revista la política editorial de la qual permet la publicació en obert Open Access.

Anàlisi del lideratge dels autors institucionals

Aquest treball s'ha realitzat amb col·laboració internacional, concretament amb investigadors de: United States of America.

Hi ha un lideratge significatiu, ja que alguns dels autors pertanyents a la institució apareixen com a primer o últim signant, es pot apreciar en el detall: Primer Autor (Sánchez Romero, Francisco Javier) .

l'autor responsable d'establir les tasques de correspondència ha estat Sánchez Romero, Francisco Javier.